TrailView ground plan GP12.3b: decks in the viewer: the shell drawn, shadows, the ladder for decks, the old near deck stops #3353

Closed

Description

@timohueser

Status: proposed
Part of #3105 (GP12, the crossing block of #3096). One pull request into ground-plan.
The steps of the block, in build order: GP12.1 #3342, GP12.2a #3343, GP12.2b #3352, GP12.3a #3344, GP12.3b #3353, GP12.4 #3345, GP12.5 #3346, GP12.6 #3347, GP12.7 #3348, GP12.8 #3349.
Read first: #3105 (words, invariants, the gallery, the costs, the owner's decisions), and GP12.3a (what the crate
builds). Short names: gp/ = host/obc-ground-plan/src/, tv/ = builder/web/src/lib/trailview/. Code places
verified on ground-plan ea4da43.

Goal

Near the eye, every bridge is one deck with an edge, an underside, a parapet or a railing on its free outline and
piers that never stand on a way below; it throws its shadow. The deck starts on a straight end line past the junction.
With too little room the deck gets thinner; with no room the two ways are ground ways and the smaller one ends. Past
the mesh range the old bridge mesh stays the far look until GP12.6, with no doubled and no missing deck.

Depends on / blocks

  • Depends on: GP12.3a (storey records, storey mesh, shell corners), GP12.1 (states, ladder), GP12.2b (ordinary ends).
  • Blocks: GP12.4, GP12.5, GP12.6, GP12.7.

Design

1. Storey 0 follows the states

in_level(.., 0) (gp/faces/mod.rs:197-206) reads the states of GP12.1 for bridge ways and for the ways that a bridge
way interrupts on ladder step 3: a DECK station is on its storey, an OPEN station on storey 0, a HIDDEN station on
none. Tunnel ways keep today's level until GP12.4. The piece of a bridge way between its tag end and A (the stub) is a
ground way of storey 0 and ends on A with GP12.2b's ordinary end.

2. The ladder for decks

  • Step 1, Full: the deck with its full depth. Step 2, Thin: first the depth goes down to deck_least_m, then the
    clearance. Step 3, Closed: both ways are ground ways of storey 0; the smaller way (GP12.1) is HIDDEN over the
    other's body and ends with GP12.2b's ordinary end; the door is GP12.5's. Step 4, At grade: a junction or a level
    crossing (exists).
  • GP2's synthetic decks (a path over a stream wider than a pipe, CrossingKind::Footbridge; an untagged way over a
    way) are decks of this step. This step moves the start of the synthetic deck over a way (gp/graph/crossings.rs: 386-400) from the lower way's clearance_m to the least room of the pair; between snap_height_m and the least room
    the pair stays Stacked (step 3).

3. Drawing the storeys and the shell

  • The WASM bridge hands the storey runs and the shell corners to the viewer (GP12.3a's option on).
  • tv/plan/corners.wgsl gives a shell corner its height: the height function of its label plus its offset, and the
    lower of two where it has two labels. tv/plan/piece.wgsl draws the storey runs and the shell with the looks of the
    table: the deck top with its way's look (markings run on over the deck), the edge faces and the underside concrete
    (timber for an unpaved deck, steel for a cable deck), parapets concrete, railings steel or timber by class.
  • Shadows: today the pieces draw no shadow casters (tv/plan/pieces.ts); the structure meshes do
    (tv/structures/structures.ts). New: a caster draw of the pieces for the storey runs, the shell and the piers.

4. The old near deck stops, and the interim far look (a new mechanism)

  • On the plan path the deck sheets replace bridges() (tv/structures/bridges.ts:39) and the corridor plan
    decksOf/teesOf of tv/roads/decks.ts near the eye.
  • Until GP12.6 builds the far forms, the old bridge mesh stays the far look. It is built per owner node into
    far.mesh (tv/structures/node.ts) as whole solids, so a vertex test cannot cut it. New: the structure pipeline
    binds the plan cells (tv/plan/cells.wgsl, as the terrain does) and discards a fragment of an old bridge mesh where
    plan_meshed holds at its position: there the cell's mesh draws, and so do its sheets. Nowhere else does a sheet
    draw. structures.wgsl discards already (:259, :263), so this adds no new loss of the early depth test. The
    mechanism goes in GP12.6.
  • The default path keeps bridges.ts and roads/decks.ts until GP19 (TrailView ground plan GP19: the ground plan becomes the only path, the old code goes, docs, budgets, merge into develop #3110).

Invariants

  1. One deck per sheet at every place near the eye: no old deck where a sheet draws, no gap where it does not. Check:
    three views of one bridge from before, inside and past the range of the meshed cells, and a top view at that line.
  2. Parapets and railings stand only on the free outline (A2, p01, B10, N1 in the gallery).
  3. The deck's underside lies over the ground under it by at least ceiling_gap_m, except where the ladder put it over
    a way or water. Check: crate test on the fixture (GP12.3a's records with the Rust heights).
  4. Every drawn shell part has its thickness and closed faces (GP12.3a's closure test holds for what is drawn).
  5. The default path does not change.

Decisions already made by the owner that apply

  • "Side-by-side bridges as one deck, small bridges and footbridges, viaducts and the far forms: do as proposed."
  • "Overlapping bridges are a super frequent issue."
  • With no room at all, a railway never ends; the smaller way ends.
  • "End walls and tunnel frames taller than 4.5 m: yes of course."
  • Structure parts are never paper-thin sheets.

Not in scope

Bores (GP12.4). The framed door (GP12.5). The far forms and the end of the interim mechanism (GP12.6). Covered bridges
(GP12.7). Rails on a deck (#3106). Guardrails on the approaches (#3115). Lamps on a deck (#3116). The footbridge hump
(deferred, #3108).

Proofs and pictures required before review

Cost to measure

Base: ground-plan at the branch point; develop's head for the frame.

  • Frame: walk, valley-drive and luz with the caster draw.
  • The corners' pass time on the GPU (plan-timing.html) with the shell corners.
  • WASM bytes, gzip and raw (the block's 15 to 25 kB).

Risks and the stop rule

  • Stop and report if the shell needs a second height function on the GPU, or a per-frame cost beyond the corners'
    pass and one more draw.
  • Stop and report if the frame reaches twice its base, or the block's WASM passes 25 kB.
  • After two failed review rounds, stop and report.

Requirements: the verification console could not be checked from this PC (no agent token here). The orchestrator sets
the pull request's Requirements: line.

Deviations (GP12.3b part A, PR #3470)

  1. The WASM cuts: graph::levels runs in the feature bake (revision 18). The zoom-13 tiles carry each road way's
    states and end lines (levels), the storey of a deck over a deck (storey) and the slab on ladder step 2 (slab);
    the device reads them (graph::level_tags::read). The bake uses the rule tables of its own build: a change of a
    level rule or of the levels' code takes a new bake, a new revision and a fixture rebake (the fixture test
    the_tiles_carry_the_levels_of_each_cell fails until then).
  2. The slab depth and the storey are per feature (the least and the highest over its cells), not per way piece. A
    way of a cell's margin reads the levels of the cell that owns it. A way with a part that has no alignment has no
    levels.
  3. Cut 3 is not done in part A: one encode pass for all storeys (not simpler than the merge, a risk to storey 0's
    bytes) and the deck stroke through the ground path (its general form is the split of the way graph at the end
    lines, which is the stub of part B). The decks measure +34.7 kB of gzip over the base (local build), not 20 to 30 kB.

Deviations (GP12.3b part B, PR #3482)

  1. Storey 0 follows the states by a split of the way graph, not by in_level(.., 0): graph::build_levelled
    (level_tags::split) splits each bridge way at the end lines that the tiles carry. A DECK stretch is a deck way, an
    OPEN stretch a ground way (the stub, which ends on A with the ordinary end), a HIDDEN stretch goes. Tunnel ways are
    not split (GP12.4). So a deck is one whole way and its stroke goes through the ground path (cut 3).
  2. The ladder runs in the bake (part A); the device reads its results from the tags. Not done: §2's start of the
    synthetic deck over a way at the least room of the pair (graph/crossings.rs is unchanged).
  3. An end of a deck is open where a ground way, or a deck on another storey, meets it at a junction or a joint,
    whatever other decks end there. The split puts each stub at its deck's height, so the rule needs no height test.
    A junction with an arm on another level is no point of a storey: each deck arm ends there open, as at a joint (no
    corner round across the other arm). Where a deck's free outline lies on a paved face of the ground whose line lies
    within 0.1 m of the deck's, it stays open, and a parapet, railing or post ends where its inner side would stand on
    such a face within a parapet's height: the deck goes on into that way.
  4. Crossing A lines of one deck group move in together, in the bake (graph::levels::merge_a, revision 19): each A
    moves in along its way to where its centre line meets the line normal to their mean direction into the decks
    through the farthest one in; its end line stays square to its own way, so on two ways at an angle the end lines can
    still cross or leave a wedge. One pass; a cell merges the A lines that it sees. Box B: 4 of 168 zoom-13 tiles
    change, the A lines move 0.01 to 1.5 m.
  5. Two deck ways side by side on a sheet are one deck; where their lines lie more than a parapet's height (1 m)
    apart at either point of an edge piece, each has its own edge face and parapet or railing there. This is new: a
    slot there was a wall from one deck to the other (Acheregg's arched footbridge, Brunnen's walkway under the road
    deck). Each piece decides from its own two points, so two cells decide alike; a parapet's or railing's chain stays
    on one deck way.
  6. Each shell corner has one label (the shell repeats a corner per label). What a deck is made of follows the rule of
    the old bridges (segment of structures/bridges.ts) per deck way (faces::deck::DeckWay::build): a road on
    beams and a railway are concrete, a bridge that hangs (bridge:structure suspension, simple-suspension or
    cable-stayed) is steel, any other (a path's, a covered one) timber; a railing is timber on timber, else steel; a
    top that the old viewer did not count as paved (main, road, oneway) is of planks on such a bridge. The device
    writes it into the storey line's finish word (bits 21 to 23; the material narrows to 4 bits), the corners pass
    copies it into the storey corners' look word, and the shell draws the timber, steel and plank looks. A rail deck has
    a railing (the class group rail joins path, steps and track in sections.rs).
  7. The old bridge mesh's faces are their own index range (MeshBuilder.bridge) and draw with their own pipeline that
    discards where a cell's mesh draws, by the same dither as a cut piece's fade (plan_share); their casters discard
    there too. The structures bind the plan cells at their own binding by an include swap (plan/cells-buffer.wgsl,
    structures/plan-cells.wgsl). A covered bridge's walls and roof stay beside the storey's deck
    (MeshBuilder.beside). roads/decks.ts draws nothing on the plan path (the corridors get no features there).
  8. Piers: each cell reads the sheet at the point of its own square nearest the pier's point, and the line, the
    ground and the tests of the foot at the pier's whole ring, so the two halves of a pier on a cell line are one
    solid. A pier's foot without a label stands on the stamp's ground (no drawn page).
  9. The slab's hollow at an open A line: the shell leaves the A line open; storey 0's end face on that line closes it
    where the ground under the deck lies lower than the deck. Where a stub meets its deck, the deck's end takes storey
    0's mesh points on the end line, and its corners there take the label of the stub's paved face or shoulder, so the
    two meshes stand at one height (invariants 4 and 5). Not on: a band over the stub's verge or slope, a deck that
    ends at a bend of its way (its stub leaves at an angle), and a few stub points inside a deck's end piece (17 seams
    on the fixture, a budget in tests/storeys.rs).
  10. N-a: the storey stays per deck group of the bake (part A); a group that crosses itself lies on one storey. Rule
    5 separates side-by-side decks of one storey that lie apart in height. No self-crossing group shows a fault at the
    Lucerne interchange.
  11. The pictures use my own box B bake of the features (revision 19) over the checkpoint 5 release, with live stamps.
  12. A bridge's abutment is concrete, not stone: a wall beside a bridge's ground stretch (a stub; its record line
    carries BRIDGE_GROUND, bit 20 of the finish word), and a wall within 3 m of a deck's stroke over storey 0 (its
    ceiling line), as at a junction at the deck's end. Its height is GP12.8's (abutments).
  13. A storey's top paints a rail deck's sleepers and rails at any distance (no faces of tracks.ts stand on a deck).

Activity

  1. timohueser commented on Nov 11, 2026

    @timohueser
    OwnerAuthor

    From GP12.1 (PR #3367): what this step can read, and what differs from the plan

    • graph.levels.runs covers every tagged way (non-synthetic deck way, non-water tunnel way) once, in order; untagged ways that end on step 3 also have runs (HIDDEN under the body, OPEN elsewhere). in_level is unchanged.
    • End lines: graph.levels.end_lines (A, Portal, Closed); merged lines list each member way with its station on the merged line, and the members' runs are moved to that station.
    • A bore stroke's wall is edge_band_m in GP12.1's sheets (the block has no wall value): GP12.4 should add one to structures.
    • deck(upper) of an untagged upper way is its deck_least_m.
    • Finding: a tunnel's tag end where the floor lies a few centimetres over the terrain gets a one-sample HIDDEN run and two closed lines (box B: many, e.g. A1 east, p04). The rule "the floor is at or under the terrain" may need a tolerance before doors are drawn (GP12.4, GP12.5).
    • Finding: on box B about a quarter of the decks are on step 2 (thin), by the least room over the paved overlap (at the centre only: about 15 %).
    • WASM: GP12.1 alone takes 25,818 B of gzip, the whole block allowance; the owner decides how the later steps are budgeted.

    Generated by Claude Code

  2. timohueser commented on Nov 12, 2026

    @timohueser
    OwnerAuthor

    From GP12.2b part 2 (PR #3396), for GP12.3b

    • Ceiling lines exist: every deck way is a CEILING line after the lines of storey 0 (finish bit 12; word 10 = drop = depth + ceiling_gap_m; words 4 and 5 = the flat-end normal per end; the samples' half-width = paved layers + edge_band_m). The stroke ends flat on the end line of the ground way that ends there (within 45°).
    • End faces draw as the mesh's last slots (head word 10) in MAT_CAP. The old deck still draws: at A2 the slit across the road at the deck start is now dark, not light.
    • W1 stays as it was in its shards: the ramps end on the cycleway (rule 2b). held_over_cap lists those steps (fx-today: 472 listed, 109 with no room).
    • S5: the heights give the opening (the road 4.7 m under the deck's bound), but the view from the road still shows a blue-grey face behind it; not located.
    • R11 and B09 get worse: the old trough cleared a wide band beside a deck; the ceiling keeps the ground only 0.5 m under the deck and lets it rise at face_max beside it. Stone cut walls stand under the R11 slab and ground rises beside the deck; at B09 the bank beside a low deck over a brook is cut into sharp facets.

    Generated by Claude Code

  3. timohueser commented on Nov 12, 2026

    @timohueser
    OwnerAuthor

    From the review of PR #3396 (GP12.2b part 2): points for this step

    The review (crossings/REVIEW-3396.md on timosPC) gives these non-blocking points to GP12.3b. PR #3396 does not fix them.

    • N1. Crease under a low deck (B09). The ceiling has a hard knee at the stroke edge (flat, then face_max per metre), and min(ground, ceiling) adds a second crease where it starts to bind. Under a low deck over a bank this gives angular facets, and the water shows in angular patches. A general softening: smin(h, ceiling, k ≈ 1 m) in by_label (Rust) and in height_relative (WGSL), identical in both. It moves heights at every place where the ceiling binds, so it needs the fixture gates and the B09 pictures again. Not done in ground plan: deck ends with end faces under the decks' ceilings #3396.
    • N2. One predicate for a deck end. lines() marks a ground arm's end DECK at any Level::Deck arm, but on_deck leaves water decks out. A ground way at a joint with a water deck gets the round slope end and the EndFace labels, but no ceiling. Use one predicate.
    • N3. A deck end with no ground arm has no abutment (plan) and no end face; the ceiling still holds the ground 0.5 m under the deck, so the deck end hangs over a shallow pit. Rare (an approach that is not mapped).
    • N4. Invariants 4 and 5 are ratchets. HeldOverCap only labels the steps; a Held step does not get the wall's limit yet (W1's 6.57 m step stays). This step must own the Held limit, and the gates HELD_OVER_CAP_MAX (74) and the 51 steep triangles at paved ends must fall to 0 here.
    • N5. Paved faces over the bound. 284 fixture points (2,810 on box B) have a paved face over the deck's bound. Report the worst: a paved face over the deck's top shows through the deck. The 22 end-line points short by over 0.1 m (most 0.35 m) are a 0.35 m ledge between the deck and the paved road (blend face), a fault of the solver or the blend.
    • N6. The drawn deck's end line. The stroke ends flat on the ground way's end line (up to FLAT_TURN_DEG). If the drawn deck ends square to its own chord, a skewed end leaves a triangle of ground held at the bound with no deck over it (up to h × h·tan θ). Check this when the storey faces draw the deck.
    • N7. Near/far. With the plan, the stamp's trough stays below level 16 and the ceiling holds from level 16 up: the ground under bridges changes shape at the change of LOD. Look for pops in a flight.

    Generated by Claude Code

  4. timohueser commented on Nov 13, 2026

    @timohueser
    OwnerAuthor

    From GP12.3a (PR #3464): what this step can read, and what differs from the plan

    • cell::build_storeys builds the storeys after storey 0 (graph::levels, then records::storeys); the bridge's feature storeys (off) runs it and gives MeshInput::storeys() (the bytes of mesh::shell::StoreyMesh) and CellPlan::storey_times().
    • WASM: with the feature the bridge is +62.1 kB gzip against ground-plan ff484a4 (levels included; local toolchain), the device without it +6.4 kB. That passes the block's 15 to 25 kB by far: this step must shrink the storey code (candidates' deck branches, faces::deck, records::storeys merge, mesh::shell) or ask the owner before it turns the feature on.
    • Block format: a storey's lines are entries after the ceiling lines (STOREY, storey in the leg bits); a storey's height segments, discs and centre-line segments come last in each bin. A storey-0 reader of the WGSL must stop at a STOREY line as at a CEILING line (h_present), the ceiling (h_ceiling) must skip the STOREY items at the end of a bin, and the paint must not take a STOREY line as a way of storey 0. A storey-k label's storey is its material line's.
    • No candidate item of a storey is in the bins: if a reader needs find on a storey, list them.
    • StoreyMesh bytes: head HEAD 16 words (MAGIC 0x4f425301, counts, triangles per part of PARTS top, underside, edge, parapet, railing, post, pier), corners of 3 words (x, y with the 25-bit label, offset f32), triangle runs per part, slot runs (tops' slots, then the undersides' risers). The cell mesh and its bytes are unchanged.
    • The stub: storey 0's selection is unchanged here, so the gap between a tag end and A shows in every picture. The deck's end line is square to the chord of the segment that holds A through A's foot on it; the stub leg should end on that line by the same rule, and split its edge on A by l_max_m of the deck faces (the storey splits its edges by its sheet faces alone).
    • Parapets and railings stand on the band (Surface::DeckEdge, rank of slope) of the free outline; the free outline leaves out cell lines and open end lines (EdgeKind::DeckEdge on the storey's plan).
    • The underside's thin depth on ladder step 2: room − least + deck_least_m, at least deck_least_m. The ceiling still holds the ground under the tile's depth.
    • Pictures: crossings/gp123a/sheets/ on timosPC (12 places, from above and oblique, Rust heights).

    Generated by Claude Code

  5. timohueser commented on Nov 13, 2026

    @timohueser
    OwnerAuthor

    From the review of PR #3464 (GP12.3a): three points for this step

    • Two decks that end at one ground junction both stay closed. A deck way's own end is open only where a ground way meets it and no other deck way does (faces::deck, ground_at). So side-by-side decks that end together at an abutment junction get an edge face where the ground road goes on. The fixture has 3 closed way ends. Check this against the stubs that this step draws.
    • The slab stays hollow at an open A line. On an open end line the deck's top, underside and slab section are left open (StoreyMesh::open), for storey 0 to meet. Something must close the slab section of depth deck there: GP12.2b's end face under the stub's end, or a free-end face of this step. Decide which, and test it with the shell closure check (mesh::shell::closure).
    • The pier foot's label depends on the cell. A pier's foot corners take storey 0's label at the middle of the pier's part in the cell (find), so for a pier on a cell line the two cells read the ground at two points. And a pier whose point lies in the neighbour cell is built only by the cell that holds its point (the sheet over it is looked up at that point): its part in the other cell is missing. Read the ground and the sheet at the pier point in both cells (the point is in both cells' inputs).

    Generated by Claude Code

  6. timohueser commented on Nov 13, 2026

    @timohueser
    OwnerAuthor

    Owner decision, 2026-11-13: "Cut, allow ~60 kB".

    The WASM allowance of the whole crossing block (GP12: decks, bores and portals, far forms, roofs) is about 60 kB gzipped on the device, in place of the earlier 15 to 25 kB. That estimate was wrong by about 3 times: the review of #3464 measured +62.1 kB gzipped for the deck code alone when the device links it (the shell about 42 %, graph::levels 25 %, the deck faces and the records merge 29 %).

    The cuts come first. They are part of GP12.3b (#3353), before the device links the storeys:

    1. graph::levels moves into the bake (planned for GP12.8): about −16 to −26 kB.
    2. The shell uses no machinery of its own (corners by sorting, sorted lists for the chains, test-only outputs out of the device): about −8 to −12 kB.
    3. The deck stroke goes through the ground path, and all storeys are encoded in one pass: about −8 to −12 kB.

    Each step of the block reports its measured device size against the base, from the CI build, and the sum against the 60 kB.


    Generated by Claude Code

  7. timohueser commented on Nov 13, 2026

    @timohueser
    OwnerAuthor

    From the delta review of PR #3464: a pier on a cell line is half a solid. The cell that holds the pier point clips the pier's box to its square, and closure does not check faces on a cell line, so the pier shows an open side there; the other cell builds no part, because the sheet lookup at the pier point fails in that cell (mesh::shell, piers). The fixture has no such pier. Fix: in each cell, find the sheet at the centre of the clipped ring (the direction along(top, pt) and the clip about pt already agree in both cells).


    Generated by Claude Code

  8. timohueser commented on Nov 13, 2026

    @timohueser
    OwnerAuthor

    From the review of PR #3470 (GP12.3b part A): points for part B

    • The ladder of a crossing is not on the device. The device does not run graph::levels, so Crossing.ladder is always None there. No device code reads it today. Anything that part B (or GP12.4) needs of a ladder, for example the start of a synthetic deck at the least room of the pair or the Stacked crossings that close, must come from a tag that the bake writes.
    • One thin crossing makes the whole OSM way thin. The slab tag is the least slab over all the crossings of the OSM way on ladder step 2, and it holds for the whole way: a 1 km viaduct with one thin crossing is thin over its full length. This removes the step in the underside at a cell line that the per-piece rule gave, but it is a change of look. Show it in the pictures of part B. A per-run slab (one slab per DECK run in levels) would keep both.
    • Two metre frames at a tile-line joint. Each zoom-13 copy of a way starts its metres along at a value rounded to 0.1 m, so at a joint on a tile line two ways can overlap or leave a gap of up to about 10 cm in metres. An end line within about 10 cm of such a vertex goes to both ways or to neither. Count it on box B before part B draws decks; if it occurs, give a line in an overlap only to the way whose tile owns that segment.
    • A bridge way with no levels draws as a synthetic deck (storey 1, full depth, no ladder). On box B every deck copy inside the bounds has the tags; the 11 without them lie past the bounds in the buffer of an edge tile, whose neighbour tile is not in the archive, so no cell of the bake holds them. On a release older than revision 18 every bridge has no levels. Part B decides the default for that case.

    Generated by Claude Code

  9. timohueser commented on Nov 13, 2026

    @timohueser
    OwnerAuthor

    From the delta review of PR #3470: two more points for part B

    • A deck group that crosses over itself lies on one storey. The deck ways that share a point are one deck group, and the bake now joins each group over all cells. A crossing of a group over itself lifts nothing, so a stack interchange whose ramps are all bridges that join on bridges lies on storey 1 as a whole, also where one ramp passes over another. Before part B draws decks, count on box B the deck-over-deck crossings whose two sides are one group, and decide the rule (for example a storey per DECK run, not per deck group).
    • Two bake areas side by side. Each bake joins only its own deck groups and measures its own metres along. A way or a deck group across the join of two bake areas can get two storeys or two sets of levels. This is a limit at the edge of a release today; if the viewer ever shows two archives in one view, the join needs its own rule.

    Generated by Claude Code

  10. timohueser commented on Nov 14, 2026

    @timohueser
    OwnerAuthor

    Part B is in ground-plan through #3482 (head 0925917, merge 46793ba), on the owner's word "Merge as it is" of 2026-11-14. Joined bridges draw as one deck; rails, timber and steel are kept; the old near decks stop where the plan draws.

    Known faults that landed with it:

    The crossing chain is at about 49 kB gzipped of the owner's allowance of about 60 kB.


    Generated by Claude Code

  11. timohueser commented on Nov 20, 2026

    @timohueser
    OwnerAuthor

    Closed in the backlog cleanup: part A (#3470) and part B (#3482) are merged. The known faults have owners: shards at deck ends → #3484; tall faces at Hergiswil and W1, and the Brunnen walkway → #3349. The two last items (section 2: the synthetic deck still starts at the old place; a deck group that crosses itself lies on one storey) are now in a comment on #3349.


    Generated by Claude Code

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment