It is a low jitter trigger box that main application is 50Hz/60 magnetic field noise cancellation.
It can be used with Stabilizer to drive a pair of coils with harmonics of 50/60Hz whose amplitude and phase are chosen to cancel out the mains-induced noise.
Features:
115/230V IEC inlet, selectable during ordering
Board takes a 9-12 V (RMS) AC input via a 2.1mm x 5.5mm x 12mm barrel connector.
50/60Hz, selectable during ordering
Selectable filerted/unfiltred mains trigger via 2.51 mm jumper.
The jumper must be placed to select one of the modes. The trigger will not operate without a jumper.