Skip to content

Authored dimension does not cover the planner's matching overall length or plane-to-axis location (duplicates remain after #2198) #2206

Closed

Description

@pzfreo

Seen on #2205 (eb72fbc). Files: https://gist.github.com/pzfreo/7c6a0be95a567e2774924207133b2d40

#2198 fixed most authored-versus-planned duplicates. Two cases still draw both the authored AP242 dimension and the planner's own for the same measurement:

  1. Overall length (specify-spindle-callouts.step). An authored Location_LinearDistance 52 +0.1/0 runs from datum A (the base face) to the top face, which is the part's overall length. The planner also draws a plain 52 beside it in the front view.
  2. Plane-to-axis location (specify-plate-callout.step). The authored basic 60, from datum C to the Ø22 bore axis, is drawn boxed below the plan. The planner also draws a plain 60 for the same measurement at the top of the plan's stack.

Expected

In both cases the authored dimension covers the planned one (as in #2187/#2198), so each measurement is drawn once, with the authored tolerance or basic box.

For context: on the same plate, 35 and 85 are no longer duplicated and the basic dimensions are boxed (#2199), so it's only these two shapes of match that are missed: an overall length, and a plane to an axis.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment