Authored basic hole locations drawn twice in the plan (35, 85, 60 on the Specify plate) #2198
35: the M6 tapped hole at x = −25. That's one hole with one authored basic location, but there are two "35" dimensions.
85: the M6 tapped hole at x = +25, also drawn twice.
60: the Ø22 bore, drawn twice (one at the top of the stack, one below the view next to the 2× R4 note).
12 and 108 also appear twice, but each of those belongs to two different holes at the same x (the 4× Ø6.6 pattern), so they are correct, though they could share one dimension.
It looks as though #2187's authored-precedence covers some planned dimensions but not these. The authored AP242 Location_LinearDistance (basic, from C to the hole's bore) is drawn, and so is a planner dimension for the same hole and direction.
Expected
One dimension per hole per direction. Where an authored location matches a planned one, the authored one stands in for it.
Activity