You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Executed on 2026-10-05: annotate 7, report 7, off 7. The seven approved values include four pattern-member diameters, the grouped pattern diameter, and two hole diameters. They carry AP242 tolerance values even in the lower-PMI members.
Cause and scope
The common annotated Document acquisition already lowers AP242 tolerances into canonical feature decorations/requirements. A later member can hide the raw source annotations by identity, but its inherited canonical measurements still carry those source tolerances. PR #2187 addresses raw authored dimension precedence; this behavior predates that PR and needs a member-specific policy for already-lowered tolerance values. Simply filtering raw AuthoredDimension features cannot undo a value already attached to a canonical feature. The fix should preserve explicit member-declared tolerances and the shared one-recognition inventory.
Acceptance
Off/report Document members do not print source AP242 tolerance overrides acquired solely for an annotate member.
Annotate member and explicit member-declared tolerance behavior stay intact.
A regression uses this CTC-03 fixture and asserts its own AP242 tolerance precondition.
Review against ADRs 1, 3, 4 and 5: one model inventory, one recognition run, explicit intent, truthful provenance.
Found during independent review of #2187; tracked separately because source-acquisition lowering must be made reversible per member across both decorations and canonical requirement fields.
Activity