Having refurbished our new home including a brand new technical installation, we've got a couple of (new) appliances that are modbus capable. So, I went looking for a python based solution in order to get grip on those devices.
I stumbled into pyubbinkext from Adam Sillye, and succeeded to read from and even write to Ubiflux Vigor W400, using a Raspberry Pi with an RS-485 hat. Though I had two more appliances to talk with: the Thermia Calibra heat-pump and the Alfen Eve Single charging station. The latter two accessible through Modbus/TCP.
So, I did want to be able to talk with three (and even more) different devices, using both serial Modbus (RS485) and Modbus/TCP, in an as flexible as possible way, equals highly configurable.
I started with pymodbus package version 'v3.6' and kept it running for a long time on a
Raspberry Pi Zero 2 W. Just recently I worked through upgrading it, up to the current
version 'v3.16.1'.
It took me a few tweaks to get/keep it running, as I did want to keep it backwards compatibility (as a sort of personal challenge). It broke twice, once at v3.7 and at v3.10. As I was running largely behind, I could have fixed and aligned my code with the latest version and leave it like that.
Nevertheless, I did want to find a solution to support two incompatible versions, and that's how I came
to pkg_proxy.py. The solution being quite simple, it works: the same code can run with pymodbus-3.6.9
up to pymodbus-3.16.1 without modification.
I have refactored the wrapper to encapsulate more into the core class.
The version 1.x required the user (program) to first create the ModbusXXXClient (devices or sockets to communicate with the appliances) and then to create the appropriate interfaces (functions applicable to the appliance). All that has now been integrated in one wrapper class ModbusWrapper.
Additionally, after an AI quality check, I replaced the dynamic code I wrote for validation (based on eval())
with a safer implementation. As proposed by Gemini AI, this resulted in the ConstraintFactory class.
- v2.1 SMA solar inverter modbus control added
- v2.0 modbus wrapper refactored with better encapsulation
- v1.1 genesis 16 protocal added
- v1.0 configuration.py moved away to application
- v0.1 Standalone (submoduled) repo
The following modbus capable appliance are implemented
- Alfen Eve Single S-Line (Alfen NG9xx platform v2.3 2020-10-30)
- Ubiflux Vigor Wxxx (Modbus UWA2-B/UWA2-E)
- Thermia Calibra (Modbus Genesis v10/v16/v17)
- copy the applicable version to
therma_functions.py(the actual file being used).
- copy the applicable version to
- SMA Solar Inverter (MODBUS-HTML_SBxx-1AV-41-GG10-V13)
The solution I finally built is contained in the core module wrapper.py.
It provides the main component (class) ModbusWrapper, providing the 'brokering' features for the program accessing
modbus connected appliances. The user program initializes the whole by creating the wrapper with its known device
configuration:
# Initialize physical devices
mdbwrapper = ModbusWrapper(NODES)So, the user program has only to define the dict NODES, defining the connection with
the appliance either as a serial device (ModbusSerialClient) or a networked device (ModbusTcpClient):
NODES = {
'vigor': {
'serial': {
'device': '/dev/ttyAMA0',
'baudrate': 19200,
},
'byteorder': '>', 'wordorder': '>',
'slave': 20,
},
'thermia': {
'tcp': {
'host': '172.16.1.14',
'port': 502,
},
'byteorder': '>', 'wordorder': '>',
'slave': 1,
},The actual modbus read or write calls are then further managed through the interfaces attached
to each device. Sample code can be found in example/main.py which relies on example/implement.py.
On a per appliance (type) basis, I have created configurations files, describing the various modbus functions supported by that device. The data got extracted from documentation provided by the supplier. Each function got a user defined name (without spaces for convenient usage in REST calls). E.g.:
'info-firmware-version': {
'address': 123,
'slave': 200,
'descr': 'Firmware version',
'len': 17, 'rd': 3, 'wr': 0, 'scale': 1,
'validate': '', 'datatype': 'str', 'unit': ''},
'msmt-current-N': {
'address': 318,
'slave': 1,
'descr': 'Current N',
'len': 2, 'rd': 3, 'wr': 0, 'scale': 1,
'validate': '', 'datatype': 'flt32', 'unit': 'A'},Observe in the example above that a different slave address can be specified per function (register) call.
The ModbusWrapper class only supports validation rules that are defined by the ConstraintFactory class.
Currently only two validation function are defined:
- in_list(0, 1, 2)
- between(0, 1000)
This can easily be extended by adding more static member functions _make_XXX to the ConstraintFactory class
@staticmethod
def _make_my_own_validation(params) -> Callable[[Any], bool]:Paul B - aka Kanutope