Skip to content

feat(nodes): a Ping panel on each node's card - #95

Merged
hiddify-com merged 2 commits into
hiddify:devfrom
Hiddify-Official:feat/node-ping
Oct 23, 2026
Merged

hiddify-com merged 2 commits into
hiddify:devfrom
Hiddify-Official:feat/node-ping

Conversation

@Hiddify-Official

Copy link
Copy Markdown
Contributor

Builds on #94 (Nodes "Show more"), and includes its commit until that one is merged: both change the node card's buttons and template. Only the last commit is this change.

Problem

"Check connection" on a node tells whether its panel answers, but not how the way to it behaves: its latency, jitter and loss.

Change

  • Endpoint GET nodes/<id>/icmp/ (nodes_api.py, super admins):
    • one ICMP echo from this panel to the node's address, the host from its link (a name resolved, IPv4 first);
    • when ICMP is not possible, the time of a TCP connect to the node's panel port, and method says which.
  • Button and panel (NodesView.vue, new components/NodePingPanel.vue): a "Ping" button next to "Open" opens a panel over that card, under the node's icon, flag and name.
    • It asks once a second until it is closed (✕, Esc, or the button again).
    • It shows the latest time (coloured), min / avg / max / loss, a bar per answer and the last 5 lines.
    • Each card has its own panel, so several nodes can be pinged at once.
    • The panel keeps its own height, whatever the card shows.
    • A long address (IPv6) ends in "…".
  • Buttons: labels never wrap ("ورود به نود" broke into three lines beside "Ping"). The row wraps instead, with delete at its end.
  • Strings in all 7 languages.

Screenshots

Before After
before after

Tested

  • On main (a parent with two nodes, panel restart):
    • real ICMP as the panel's service user, about 50 ms to one node and 151 ms over IPv6 to the other;
    • both panels running at once;
    • the panel keeps its height on a card with its charts open;
    • the ✕ stays inside and the IPv6 address is cut with "…";
    • an unknown node answers 404.
  • Shown on desktop, dark, mobile and Persian RTL.

Review

  • Confidence: High (>90%) — the endpoint only runs ping -c 1 (an argument list, no shell) to the stored node's address. Tested on main.
  • Complexity: Simple — one endpoint and one panel.

🤖 Generated with Claude Code

Hiddify-Official and others added 2 commits October 23, 2026 12:12
…arts

Each node card has a "Show more" toggle under its buttons that opens the
node's live charts: network up/down, CPU and RAM, drawn like the
dashboard's Node health but for that node only. One feed (the dashboard's
system snapshot, which lists every node) runs every 5 s while a card is
open and keeps 60 samples: the last 5 minutes.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…losed

A "Ping" button on each node card opens a panel over that card, under its
name: this panel pings the node's server once a second (ICMP, or the time
of a TCP connect to its panel port when ICMP is not possible) until the
panel is closed, with the latest time, min / avg / max / loss, a bar per
answer and the last lines. Each card has its own, so several nodes can be
pinged at once.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@github-actions

Copy link
Copy Markdown

🥷 Ninja i18n – 🛎️ Translations need to be updated

Project /project.inlang

lint rule new reports level link
Identical pattern 10 warning contribute (via Fink 🐦)

@hiddify-com
hiddify-com merged commit 0e67444 into hiddify:dev Oct 23, 2026
1 check passed
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment