25 changes: 24 additions & 1 deletion process-node-stm32/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -60,7 +60,8 @@ practice; `can selftest` checks it. If it is ever flaky, put a TXS0108E in betwe
- UART sensor (emulated by the pod) on USART3: **LA8 -> PC11 (RX), PC10 (TX) -> LA7**. Closed
(both pins inputs) until `uart3 open`.

All LA wiring at a glance (the `wiring` fixture in `tests/conftest.py` is the same table):
All LA wiring at a glance. [`wiring/process-node-stm32.json`](wiring/process-node-stm32.json) is the
same table as a wiring profile (see [Wiring profile](#wiring-profile)):

| LA | Nucleo | Signal | Driven by |
|---|---|---|---|
Expand All @@ -79,6 +80,28 @@ All LA wiring at a glance (the `wiring` fixture in `tests/conftest.py` is the sa
| LA13 | PB14 | SPI2 MISO | pod |
| LA14 | PB12 | SPI2 CS | node |

### Wiring profile

This bench is not wired like the pod's default pins (UART RX on LA5, I2C SDA on LA1 and SCL on LA2):
here the console is on LA3/LA4, I2C SCL on LA1 and SDA on LA2, and LA5 is the alarm. The bench has
its own wiring profile, [`wiring/process-node-stm32.json`](wiring/process-node-stm32.json), with every
pin in the table above: the roles (UART, I2C, SWD with NRST), the named signals (`ALARM`, `STROBE`,
`SENSOR_UART_*`, `SENSOR_SPI_*`), 3.3 V I/O and internal 5 V target power.

Store it on the pod once, under its own name, so the web app, BenchPod Desktop, the CLI, the SDK and
an AI agent all find it:

```bash
benchpod wiring save process-node-stm32/wiring/process-node-stm32.json --name process-node-stm32
```

Saving does not change the pod's default profile (unless it is the pod's first profile). The HIL
tests load it by name (`bp.load_wiring("process-node-stm32")`) and stop with that command when the
pod does not have it. In your own scripts, `BenchPod(conn, wiring_profile="process-node-stm32")`, or
in an agent, `connect(wiring_profile="process-node-stm32")`, does the same. A run that names its own
wiring (`--benchpod-wiring`, `--benchpod-wiring-profile`, `BENCHPOD_WIRING`,
`BENCHPOD_WIRING_PROFILE`) uses that instead.

## Build

```bash
Expand Down
81 changes: 60 additions & 21 deletions process-node-stm32/tests/conftest.py
Original file line number Diff line number Diff line change
Expand Up @@ -9,6 +9,10 @@
runs one group. Wires that are not on every bench yet gate their tests with an environment
variable: BENCH_NEW_WIRING=1 (SPI2 on LA9/LA10/LA13/LA14, USART3 on LA7/LA8) and BENCH_LA6_RESISTOR=1 (the
1 kOhm between PA8 and LA6 that lets the pod drive a data-ready line into PA8).

The LA channels come from the bench's wiring profile, ``wiring/process-node-stm32.json``, stored on the
pod under the name ``process-node-stm32`` and loaded by that name (``bp.load_wiring``) for the run.
The pod's default profile is not used or changed.
"""

import contextlib
Expand Down Expand Up @@ -126,31 +130,66 @@ def benchpod_la_voltage():
return 3.3 # NUCLEO-F446RE I/O voltage


#: The bench's wiring profile, stored on the pod under this name (README, "Wiring profile").
WIRING_PROFILE = "process-node-stm32"
WIRING_FILE = Path(__file__).resolve().parent.parent / "wiring" / f"{WIRING_PROFILE}.json"


def _explicit_wiring(config):
"""True when the run names its own wiring (--benchpod-wiring, --benchpod-wiring-profile,
BENCHPOD_WIRING or BENCHPOD_WIRING_PROFILE): then the conftest does not load its profile."""
return bool(config.getoption("benchpod_wiring") or config.getoption("benchpod_wiring_profile")
or os.environ.get("BENCHPOD_WIRING") or os.environ.get("BENCHPOD_WIRING_PROFILE"))


@pytest.fixture(scope="session")
def wiring(pins):
"""How THIS bench is wired: DUT signal -> BenchPod LA channel."""
def bench_profile(benchpod, pytestconfig):
"""The pod's ``process-node-stm32`` wiring profile, loaded by name for this connection (the
pod's default profile stays as it is). A run that names its own wiring keeps that one."""
if _explicit_wiring(pytestconfig):
return benchpod.wiring
if benchpod.stored_wiring(WIRING_PROFILE) is None:
pytest.exit(f"the pod has no wiring profile {WIRING_PROFILE!r}; store it once with "
f"`benchpod wiring save {WIRING_FILE} --name {WIRING_PROFILE}` "
f"(or run with --benchpod-wiring {WIRING_FILE})", returncode=4)
return benchpod.load_wiring(WIRING_PROFILE)


@pytest.fixture(scope="session")
def wiring(bench_profile, pytestconfig):
"""How THIS bench is wired, read from its wiring profile (wiring/process-node-stm32.json)."""
prof = bench_profile

def la(name):
try:
return prof.la(name)
except ValueError:
pytest.exit(f"wiring profile {prof.profile_name or 'in use'!r} has no {name}; it must match "
f"{WIRING_FILE.name}", returncode=4)

return SimpleNamespace(
swclk=pins.pin_11,
swdio=pins.pin_12,
nreset=True,
uart_rx=pins.pin_3, # pod samples the DUT's TX here
uart_tx=pins.pin_4, # pod drives the DUT's RX here
efuse=pins.efuse,
i2c_scl=pins.pin_1, # PB8, the pod emulates the BMP280 here
i2c_sda=pins.pin_2, # PB9
alarm=pins.pin_5, # PB0, high while any alarm is active
strobe=pins.pin_6, # PA8, marks ADC samples / control steps / env reads
swclk=la("swd_swclk"),
swdio=la("swd_swdio"),
nreset=prof.swd_nreset,
target=prof.swd_target or TARGET_CFG,
uart_rx=la("uart_rx"), # LA3: the pod samples the DUT's TX here
uart_tx=la("uart_tx"), # LA4: the pod drives the DUT's RX here
efuse=pytestconfig.getoption("benchpod_efuse") or prof.efuse or 1,
i2c_scl=la("i2c_scl"), # LA1, PB8, the pod emulates the BMP280 here
i2c_sda=la("i2c_sda"), # LA2, PB9
alarm=la("ALARM"), # LA5, PB0, high while any alarm is active
strobe=la("STROBE"), # LA6, PA8, marks ADC samples / control steps / env reads
# The same LA6 wire, through 1 kOhm: an emulated sensor's data-ready output into PA8
# (PA8 is an input while the strobe is off). Only the data-ready tests drive it.
drdy=pins.pin_6,
drdy=la("STROBE"),
# SPI2 to the emulated SPI sensor; the pod drives only MISO (and only while CS is low).
spi_sclk=pins.pin_9, # PB13 SCK, DUT drives
spi_mosi=pins.pin_10, # PB15 MOSI, DUT drives
spi_miso=pins.pin_13, # PB14 MISO, pod drives
spi_cs=pins.pin_14, # PB12 CS, DUT drives (software CS)
spi_sclk=la("SENSOR_SPI_SCK"), # LA9, PB13 SCK, DUT drives
spi_mosi=la("SENSOR_SPI_MOSI"), # LA10, PB15 MOSI, DUT drives
spi_miso=la("SENSOR_SPI_MISO"), # LA13, PB14 MISO, pod drives
spi_cs=la("SENSOR_SPI_CS"), # LA14, PB12 CS, DUT drives (software CS)
# USART3 to the emulated UART sensor.
sensor_uart_tx=pins.pin_8, # pod -> PC11 USART3 RX
sensor_uart_rx=pins.pin_7, # PC10 USART3 TX -> pod
sensor_uart_tx=la("SENSOR_UART_TX"), # LA8, pod -> PC11 USART3 RX
sensor_uart_rx=la("SENSOR_UART_RX"), # LA7, PC10 USART3 TX -> pod
# Analog in: pod 3.3 V DAC SMA -> 5-10 kOhm -> PA1 (Nucleo A1). PROCESS_NODE_ANALOG=0 on a
# bench without that lead skips the analog tests instead of failing them.
ain_path="3v3",
Expand All @@ -175,13 +214,13 @@ def _flash(bp, wiring, firmware):
if attempt > 0:
bp.power_off(wiring.efuse)
result = bp.flash(
file=firmware, target=TARGET_CFG,
file=firmware, target=wiring.target,
swclk=wiring.swclk, swdio=wiring.swdio, nreset=wiring.nreset,
target_power=wiring.efuse, check=False,
)
if not result.ok and result.target_unreachable and wiring.nreset:
result = bp.flash(
file=firmware, target=TARGET_CFG,
file=firmware, target=wiring.target,
swclk=wiring.swclk, swdio=wiring.swdio, nreset=False,
target_power=wiring.efuse, check=False,
)
Expand Down
33 changes: 33 additions & 0 deletions process-node-stm32/wiring/process-node-stm32.json
Original file line number Diff line number Diff line change
@@ -0,0 +1,33 @@
{
"version": 2,
"la_mv": 3300,
"efuse": 1,
"uart_rx": 3,
"uart_tx": 4,
"uart_baud": 115200,
"i2c_scl": 1,
"i2c_sda": 2,
"i2c_addr": "0x76",
"swd_swclk": 11,
"swd_swdio": 12,
"swd_nreset": true,
"swd_target": "target/stm32f4x.cfg",
"signals": [
{"name": "ALARM", "la": 5, "direction": "input", "active_low": false,
"description": "PB0, high while any alarm is active"},
{"name": "STROBE", "la": 6, "direction": "bidir", "active_low": false,
"description": "PA8 via 1 kOhm: the node's strobe, or a data-ready line the pod drives"},
{"name": "SENSOR_UART_RX", "la": 7, "direction": "input", "active_low": false,
"description": "PC10 USART3 TX -> pod (emulated UART sensor)"},
{"name": "SENSOR_UART_TX", "la": 8, "direction": "output", "active_low": false,
"description": "pod -> PC11 USART3 RX (emulated UART sensor)"},
{"name": "SENSOR_SPI_SCK", "la": 9, "direction": "input", "active_low": false,
"description": "PB13 SPI2 SCK (emulated SPI sensor, the node drives)"},
{"name": "SENSOR_SPI_MOSI", "la": 10, "direction": "input", "active_low": false,
"description": "PB15 SPI2 MOSI (the node drives)"},
{"name": "SENSOR_SPI_MISO", "la": 13, "direction": "output", "active_low": false,
"description": "PB14 SPI2 MISO (the pod drives, only while CS is low)"},
{"name": "SENSOR_SPI_CS", "la": 14, "direction": "input", "active_low": true,
"description": "PB12 SPI2 CS (the node drives)"}
]
}