Repository navigation
current_in: the pod's sense resistance, 100 ohm on analog module v3r5 - #120
Merged
Merged
Conversation
Analog module v3r5 has a 100 ohm sense resistor on the 4-20 mA input (249 ohm before), and firmware 3.10.13+ reports what it converts with (sense_mohm). - AdcReading.sense_ohms and Calibration.sense_ohms. - capture_adc / capture_correlated on current_in compute currents with the pod's value (249 ohm when the firmware does not say). - On v3r5 the pod reads current_in in the low range by default and gives it back on the next route: the SDK follows, also after a DAC output route (dac_output, generate, replay) where the pod does not report the range. - MCP adc_read returns sense_ohms; the guide explains the 30 mA limiter. - README, changelogs, API snapshot. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…inned SDK) Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…elease row) Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
wardviaene
enabled auto-merge (squash)
November 19, 2026 17:34
wardviaene
force-pushed
the
current-in-100r
branch
from
November 19, 2026 17:34
658aefa to
7255b6c
Compare
Merged
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Analog module v3r5 has a 100 ohm sense resistor on the 4-20 mA input (249 ohm before). Firmware 3.10.13+ (embeddedci-com/benchpod-firmware#174) reports what it converts with as
sense_mohm, and readscurrent_inin the ADC low range unless a range is given.AdcReading.sense_ohms,Calibration.sense_ohms(None on older firmware, which is always 249 ohm).capture_adc/capture_correlatedoncurrent_incomputecurrentswith the pod's value, 249 ohm when it does not say.dac_output,generate,replay), where the pod puts the range back without reporting it. A range the user chose is left alone.adc_readreturnssense_ohms; the guide mentions the 30 mA limiter (readings stuck near 28.5 to 31.5 mA).Tests: new
test_current_in_shunt.py(v3r4 and v3r5 fakes: readings, captures, the automatic range and its return), MCP tool test.make test: 1054 / 209 / 74 / 12 passed (withBENCHPOD_FIRMWARE_DIRpointing at a current firmware checkout for the feature map check).Not hardware-tested: no v3r5 module exists yet. Not released.
🤖 Generated with Claude Code