9 changes: 7 additions & 2 deletions .github/workflows/connector-tests.yml
Original file line number Diff line number Diff line change
Expand Up @@ -189,8 +189,11 @@ jobs:
env:
GCP_GSM_CREDENTIALS: ${{ secrets.GCP_GSM_CREDENTIALS }}
POETRY_DYNAMIC_VERSIONING_BYPASS: "0.0.0"
# The Docker read runs in the "Container Build and Test" step below; skip it here so it
# does not run twice.
run: |
poetry run airbyte-cdk connector test
poetry run airbyte-cdk connector test \
--pytest-arg=--read-from-streams=false

# Manifest-only connector images are built `FROM` the published `source-declarative-manifest`
# base image declared in metadata.yaml, so by default the container tests exercise the
Expand All @@ -212,6 +215,7 @@ jobs:
# branch-built SDM base image here too. Otherwise those tests build the connector image
# `FROM` the published metadata base image (running the released CDK instead of this
# branch's), and the later `image test` step can't reuse its layers.
# The Docker read runs in the later `image test` step, so it is skipped here.
- name: Run FAST Standard Tests [Manifest-Only Connectors]
if: env.CONNECTOR_LANGUAGE == 'manifest-only'
working-directory: airbyte-python-cdk
Expand All @@ -221,7 +225,8 @@ jobs:
run: |
poetry run airbyte-cdk connector test ${{ matrix.connector }} \
--pytest-arg=--connector-base-image \
--pytest-arg=airbyte/source-declarative-manifest:dev
--pytest-arg=airbyte/source-declarative-manifest:dev \
--pytest-arg=--read-from-streams=false

- name: Container Build and Test [All Connectors]
if: steps.no_changes.outputs.status != 'cancelled'
Expand Down
159 changes: 132 additions & 27 deletions airbyte_cdk/test/standard_tests/docker_base.py
Original file line number Diff line number Diff line change
Expand Up @@ -34,6 +34,10 @@
assert_check_outcome,
assert_config_matches_spec,
)
from airbyte_cdk.test.standard_tests._read_assertions import (
assert_read_records,
assert_schema_validation_opt_out_allowed,
)
from airbyte_cdk.test.standard_tests._spec_compatibility import (
DEPLOYMENT_MODE_ENV_VARS,
REGISTRY_UNAVAILABLE_ERRORS,
Expand Down Expand Up @@ -146,6 +150,71 @@ def get_read_streams(
return streams


DEFAULT_READ_SCENARIO_IDS: tuple[str, ...] = ("config", "valid_config", "default")
"""The config ids (file names without `.json`) that `--read-scenarios=default` reads."""


def get_default_read_scenario_ids(scenarios: list[ConnectorTestScenario]) -> set[str]:
"""Return the ids of the configs that the Docker read test reads under `--read-scenarios=default`.

These are the read configs named in `DEFAULT_READ_SCENARIO_IDS`. A connector that names none of
its read configs that way reads its first read config instead, so the default never skips
every Docker read of a connector. Configs expected to fail are never picked.
"""
read_ids = [
scenario.id
for scenario in scenarios
if scenario.runs("read") and not scenario.expected_outcome.expect_exception()
]
preferred = {
scenario_id for scenario_id in read_ids if scenario_id in DEFAULT_READ_SCENARIO_IDS
}
return preferred or set(read_ids[:1])


def select_docker_read_streams(
read_streams: list[AirbyteStream],
*,
read_from_streams: Literal["all", "default"] | list[str],
suggested_streams: list[str] | None,
) -> list[AirbyteStream]:
"""Narrow a config's read streams by `--read-from-streams` (see the `read_from_streams` fixture).

`default` keeps the connector's suggested streams, unless it declares none or none of them is
read for this config: then every stream is kept, as `all` does. A stream list keeps the listed
streams, which may leave none.
"""
if isinstance(read_from_streams, list):
wanted = set(read_from_streams)
return [stream for stream in read_streams if stream.name in wanted]

if read_from_streams == "default" and suggested_streams:
suggested = set(suggested_streams)
narrowed = [stream for stream in read_streams if stream.name in suggested]
if narrowed:
return narrowed

return read_streams


CONNECTOR_WORKDIR = "/source"
"""The connector's working directory in the Docker tests: the platform's, for a source."""

CONNECTOR_WORKDIR_ARGS: tuple[str, ...] = (
"--tmpfs",
f"{CONNECTOR_WORKDIR}:rw,exec,mode=1777",
"--workdir",
CONNECTOR_WORKDIR,
)
"""`docker run` arguments that give the connector a writable working directory, as the platform does.

The platform runs a connector with its working directory on a writable volume. An image's own
`WORKDIR` is usually not writable by the image's non-root user, so a connector that writes a
temporary file to its working directory (a bulk export download, for example) would fail only in
the tests.
"""


_SPEC_FAILURE_OUTPUT_LINES = 50
"""How many trailing lines of the connector's output a failed `spec` run reports."""

Expand Down Expand Up @@ -689,6 +758,7 @@ def test_docker_image_build_and_check(
"docker",
"run",
"--rm",
*CONNECTOR_WORKDIR_ARGS,
"-v",
f"{temp_config_file}:{container_config_path}:rw",
connector_image,
Expand Down Expand Up @@ -804,6 +874,7 @@ def test_docker_image_build_and_discover(
"docker",
"run",
"--rm",
*CONNECTOR_WORKDIR_ARGS,
"-v",
f"{temp_config_file}:{container_config_path}:rw",
connector_image,
Expand All @@ -829,14 +900,26 @@ def test_docker_image_build_and_read(
read_from_streams: Literal["all", "none", "default"] | list[str],
read_scenarios: Literal["all", "none", "default"] | list[str],
) -> None:
"""Read from the connector's Docker image.
"""Read from the connector's Docker image, and check the records as `test_basic_read` does.

This test builds the connector image and runs a full-refresh `read` command inside the
container, for configs listed under `basic_read` or `full_refresh` in
`acceptance-test-config.yml`. The read covers the streams of the config's
`configured_catalog_path`, or every discovered stream when it declares none, minus its
`empty_streams` (see `get_read_streams`), narrowed further by `--read-from-streams`.

The records get the same checks as in `test_basic_read`: a config listed under
`basic_read` must return at least one record from every stream it reads, and every record
must match its stream's JSON schema (opt out with `validate_schema: false`, which a
connector at `test_strictness_level: high` cannot). A config listed only under
`full_refresh` must return some records.

The test runs by default. `--read-scenarios` picks which configs are read (by default
`config`, `valid_config` and `default`, or the first read config when a connector has
none of those), and `--read-from-streams` which of their streams (by default the
connector's suggested streams); `--read-from-streams=false` (or `none`) skips the test. See the
`read_from_streams` and `read_scenarios` fixtures.

Note:
- If the --connector-image arg is provided, it will be used instead of building the image.
"""
Expand All @@ -849,25 +932,31 @@ def test_docker_image_build_and_read(
pytest.skip("Skipping (expected to fail).")

if read_from_streams == "none":
pytest.skip("Skipping read test (`--read-from-streams=false`).")
pytest.skip(
"Skipping the Docker read test: it was disabled with `--read-from-streams`."
)

if read_scenarios == "none":
pytest.skip("Skipping (`--read-scenarios=none`).")
pytest.skip("Skipping the Docker read test: it was disabled with `--read-scenarios`.")

default_scenario_ids = ["config", "valid_config", "default"]
if read_scenarios == "all":
pass
elif read_scenarios == "default":
if scenario.id not in default_scenario_ids:
if read_scenarios == "default":
default_ids = get_default_read_scenario_ids(self.get_scenarios())
if scenario.id not in default_ids:
pytest.skip(
f"Skipping read test for scenario '{scenario.id}' "
f"(not in default scenarios list '{default_scenario_ids}')."
f"Skipping the Docker read of config '{scenario.id}': "
f"`--read-scenarios=default` reads {', '.join(sorted(map(repr, default_ids)))}. "
"Pass `--read-scenarios=all` to read every config."
)
elif scenario.id not in read_scenarios:
# pytest.skip(
raise ValueError(
f"Skipping read test for scenario '{scenario.id}' "
f"(not in --read-scenarios={read_scenarios})."
elif read_scenarios != "all" and scenario.id.lower() not in read_scenarios:
pytest.skip(
f"Skipping the Docker read of config '{scenario.id}': not in "
f"`--read-scenarios={','.join(read_scenarios)}`."
)

if scenario.is_basic_read_config:
assert_schema_validation_opt_out_allowed(
validate_schema=scenario.validate_schema,
test_strictness_level=scenario.test_strictness_level,
)

connector_root = self.get_connector_root_dir()
Expand Down Expand Up @@ -895,6 +984,7 @@ def test_docker_image_build_and_read(
"docker",
"run",
"--rm",
*CONNECTOR_WORKDIR_ARGS,
"-v",
f"{temp_config_file}:{container_config_path}:rw",
connector_image,
Expand All @@ -905,19 +995,22 @@ def test_docker_image_build_and_read(
raise_if_errors=True,
)

read_streams = get_read_streams(
scenario,
get_discovered_streams(discover_result, connector_name),
connector_root,
suggested_streams = metadata.data.suggestedStreams
read_streams = select_docker_read_streams(
get_read_streams(
scenario,
get_discovered_streams(discover_result, connector_name),
connector_root,
),
read_from_streams=read_from_streams,
suggested_streams=suggested_streams.streams if suggested_streams else None,
)
if read_from_streams == "default" and metadata.data.suggestedStreams:
# Read only the suggested streams.
suggested_streams = set(metadata.data.suggestedStreams.streams)
read_streams = [s for s in read_streams if s.name in suggested_streams]

if isinstance(read_from_streams, list):
# If `read_from_streams` is a list, read only those streams.
read_streams = [s for s in read_streams if s.name in read_from_streams]
if not read_streams and isinstance(read_from_streams, list):
pytest.skip(
f"Skipping the Docker read of config '{scenario.id}': none of the streams in "
f"`--read-from-streams={','.join(read_from_streams)}` is "
"read for it."
)

configured_catalog: ConfiguredAirbyteCatalog = ConfiguredAirbyteCatalog(
streams=[
Expand All @@ -938,6 +1031,7 @@ def test_docker_image_build_and_read(
"docker",
"run",
"--rm",
*CONNECTOR_WORKDIR_ARGS,
"-v",
f"{temp_config_file}:{container_config_path}:rw",
"-v",
Expand All @@ -951,3 +1045,14 @@ def test_docker_image_build_and_read(
],
raise_if_errors=True,
)

if scenario.is_basic_read_config:
# Also asserts that the read returned records, in the same pass over them.
assert_read_records(
records=read_result.records_iterator,
configured_catalog=configured_catalog,
require_records_per_stream=True,
validate_schema=scenario.validate_schema,
)
elif next(read_result.records_iterator, None) is None:
raise AssertionError("Expected records but got none.")
Loading