Skip to content

Calibration using 100Ohm #7

Description

@JochiSt

I tested the OFM using two 100 Ohm resistors and a DAC sweep. (From the calibration, it is known, that 32 LSB DAC are about 1mA measurement current)

Channel 0

measurement_20220309_065823_CH0_1023

Channel 1

measurement_20220309_065823_CH1_1023

Overall it seems, that there is a bit to much noise for the low voltages (and currents). This needs further investigations, whether there is some room for improvements.