@mhareznik

Problem

In the TcoAnalogueInspector in the TcoInspectors library, the retry action does not work correctly unless the inspector task is restored before retrying the inspection.

Current workaround

Currently, application engineers have to jump to the retry/inspection step with a minimum delay of 2 contextual PLC cycles before executing the retry action
-or-
manually restore _inspectorTask before retrying inspection on each track:

IF IsFreshState THEN 
    station.CuProcessData.PresentPartTrack1._inspectorTask.Restore();
    station.CuProcessData.PresentPartTrack2._inspectorTask.Restore();
END_IF

Activity

  1. added
    bugSomething isn't working
    questionFurther information is requested
    on May 18, 2026
  2. peterbarancek commented on Jun 15, 2026

    @peterbarancek
    Collaborator

    solved in InspectorGroupRetryToSame