Repository navigation
Measure game object retention after grid handover - #181
Open
viktor-ferenczi wants to merge 4 commits into
Open
viktor-ferenczi wants to merge 4 commits into
viktor-ferenczi wants to merge 4 commits into
Conversation
…Works/cluster into codex/cluster-grid-reference-lifetime
… codex/cluster-grid-reference-lifetime
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Compare strong and weak-only game-object references across a real grid handover and a replicated safe-zone deletion. The test plugin records the entity type, process, live lookup and source ModAPI
OnClosecount. It flushes normal game callbacks and observes forced collections before and after dropping the explicit root.On Linux with cluster 0.3.32 the three paired cases passed in 77.6 seconds. Both grids and both batteries arrived on node 2 under the original game IDs. Deleting the two admin safe zones removed their local copies from both regular nodes. Each of the six source objects delivered exactly one close event.
The grid’s sampled slim armor block and physics wrapper collected while its grid object was still held. Two prior ordinary-grid runs gave the same strong/weak result in 62.8 and 61.8 seconds. The report tracks individual managed objects; it supplies no byte-level heap attribution. A weak-only or released instance that survives the observation window yields an inconclusive result. SE-1845 observations