FactoryFlow gateway

HMI -> REST -> FastAPI -> TCP -> C++ Controller + Plant Simulator

The Next.js HMI is the operator-facing caller. FastAPI only translates HTTP requests to TCP messages and returns the C++ response. It contains no sensor simulation, conveyor rules, state transitions, or fault decisions. C++ remains the owner of the machine state and runs its approximately 10 ms cycle independently of HTTP requests. A gateway failure does not stop the C++ loop.

Run locally

From the repository root (Python 3.10+, C++20, CMake 3.20+):

cmake -S . -B build
cmake --build build
python3 -m venv gateway/.venv
gateway/.venv/bin/python -m pip install -r gateway/requirements.txt
./build/factoryflow --serve

In another terminal:

gateway/.venv/bin/python -m uvicorn gateway.main:app --host 127.0.0.1 --port 8000

The C++ TCP server listens on 127.0.0.1:9000. Service mode starts IDLE and waits for start; it remains available in COMPLETE and FAULT. Stop the processes with Ctrl-C. Running ./build/factoryflow without arguments retains the standalone automatic demo. The TCP implementation uses POSIX sockets (macOS/Linux).

curl http://127.0.0.1:8000/api/status
curl -X POST http://127.0.0.1:8000/api/start
curl -X POST http://127.0.0.1:8000/api/stop
curl -X POST http://127.0.0.1:8000/api/reset

No request bodies are required. All successful endpoints return the C++ status snapshot: state, inputs, and outputs. Status reflects the completed cycle, including sensors updated after plant movement. There is no gateway-side cache. FACTORYFLOW_HOST and FACTORYFLOW_PORT configure the gateway's TCP destination; the bundled C++ server uses the fixed loopback address above.

Command semantics belong to C++

Command C++ application behavior
status Read the current snapshot without changing the run.
start Enable cyclic scans; repeated start during a run is harmless. COMPLETE or FAULT returns reset_required.
stop Set the existing simulated emergency-stop input. The unchanged controller scans it, latches FAULT, and disables all outputs before acknowledgement.
reset Reinitialize the virtual experiment: new Controller, box at entry, simulated faults cleared, outputs off, waiting for start. Can also abort an active virtual run.

The existing controller has no normal-stop or reset inputs. These commands are therefore simulator lifecycle operations in main.cpp, not additions to Controller::scan() or the ST controller. Stop is deliberately not pause/resume. Reset here resets a virtual plant; it is not a physical machine reset procedure.

TCP protocol

One connection carries one request and one response, then the server closes it. Each frame is UTF-8 JSON followed by LF (\n). Requests are deliberately restricted to these four literal JSON strings, with optional surrounding spaces/tabs/CR:

"status"\n
"start"\n
"stop"\n
"reset"\n

Here \n denotes an actual newline byte. Requests are not JSON objects. Escaped spellings, extra fields, multiple requests per connection, and other tokens are not supported. The C++ implementation matches these fixed tokens without a JSON library. A request may be split across TCP packets; the newline ends the frame. The request limit is 128 bytes including LF. Invalid requests return {"error":"invalid_request"}; rejected starts return {"error":"reset_required"}. Neither executes the requested operation.

Example successful response (one line on the wire):

{"state":"TRANSPORTING","inputs":{"entrySensor":false,"sortingSensor":false,"laneBSensor":false,"emergencyStop":false,"motorFault":false},"outputs":{"conveyorMotor":true,"diverterA":false,"diverterB":false,"diverterC":false}}

The server handles one active connection at a time with nonblocking reads/writes and a one-second connection deadline, continuing scans while waiting for bytes. The gateway uses a two-second socket timeout and a 4 KiB response limit. TCP disconnects do not reset or stop the simulation. There are no automatic retries: after a lost reply, a command may already have executed; query status before retrying.

HTTP result Meaning
200 C++ accepted the request and returned a snapshot.
409 C++ rejected the command; detail contains its error.
502 C++ returned an invalid or incomplete protocol response.
503 C++ connection failed or timed out.

Tests

Stop manually launched services before integration tests (they use port 9000).

ctest --test-dir build --output-on-failure
gateway/.venv/bin/python -m pytest gateway/tests -q

Gateway unit tests verify forwarding and error translation, using FastAPI's TestClient. Integration tests launch the built C++ process, exercise all endpoints, check Lane B completion, and test fragmented, invalid, and stalled TCP requests. They skip if the C++ executable has not been built. No control algorithm is reproduced in Python.