Skip to content

Commit 6d84e23

Browse files
committed
hardware: add connector informations
Signed-off-by: Michael Heimpold <michael.heimpold@chargebyte.com>
1 parent 2b28f91 commit 6d84e23

1 file changed

Lines changed: 24 additions & 3 deletions

File tree

docs/source/hardware.rst

Lines changed: 24 additions & 3 deletions
Original file line numberDiff line numberDiff line change
@@ -10,14 +10,31 @@ The following figure shows the Charge Control Y from a front view with numbered
1010

1111
.. figure:: _static/images/ccy_pinout.svg
1212
:width: 900px
13-
:alt: CCY pinout (front view)
13+
:alt: Charge Control Y Pinout (Front View)
1414
:align: center
1515

16-
Charge Control Y pinout (front view)
17-
16+
Charge Control Y Pinout (Front View)
17+
18+
The following table lists the connector types on Charge Control Y side and a matching
19+
counterpart example cable.
20+
21+
+----------------+-----------+---------+--------+----------------------------------------------------------------------------------------------------------------------------------+
22+
| Connector | Pin Count | Coding | Gender | Example Counterpart Part Number/Link |
23+
+================+===========+=========+========+==================================================================================================================================+
24+
| Power & Safety | 5 | A | Male | `Phoenix Contact 1476893 <https://www.phoenixcontact.com/de-de/produkte/sensor-aktor-kabel-sac-5p-15-pur-p12fs-sh-1476893>`__ |
25+
+----------------+-----------+---------+--------+----------------------------------------------------------------------------------------------------------------------------------+
26+
| Profinet | 5 | D | Female | |
27+
+----------------+-----------+---------+--------+ `Phoenix Contact 1476024 <https://www.phoenixcontact.com/en-pc/products/network-cable-nbc-p12msd-20-93e-r4ac-1476024>`__ |
28+
| LAN (OCPP) | 5 | D | Female | |
29+
+----------------+-----------+---------+--------+----------------------------------------------------------------------------------------------------------------------------------+
30+
| MCS | 8 | A | Female | |
31+
+----------------+-----------+---------+--------+ `Phoenix Contact 1522778 <https://www.phoenixcontact.com/en-pc/products/sensor-actuator-cable-sac-8p-m12ms-15-pur-sh-1522778>`__ |
32+
| IO | 8 | A | Female | |
33+
+----------------+-----------+---------+--------+----------------------------------------------------------------------------------------------------------------------------------+
1834

1935
Power & Safety
2036
^^^^^^^^^^^^^^
37+
2138
.. list-table::
2239
:widths: 15 85
2340
:header-rows: 1
@@ -41,6 +58,7 @@ Power & Safety
4158

4259
Profinet
4360
^^^^^^^^
61+
4462
.. list-table::
4563
:widths: 15 85
4664
:header-rows: 1
@@ -64,6 +82,7 @@ Profinet
6482

6583
LAN (OCPP)
6684
^^^^^^^^^^
85+
6786
.. list-table::
6887
:widths: 15 85
6988
:header-rows: 1
@@ -87,6 +106,7 @@ LAN (OCPP)
87106

88107
MCS
89108
^^^
109+
90110
.. list-table::
91111
:widths: 15 85
92112
:header-rows: 1
@@ -116,6 +136,7 @@ MCS
116136

117137
IO
118138
^^
139+
119140
.. list-table::
120141
:widths: 15 85
121142
:header-rows: 1

0 commit comments

Comments
 (0)