diff --git a/CHANGELOG.md b/CHANGELOG.md index 64ccdba2..3a6dd8d5 100644 --- a/CHANGELOG.md +++ b/CHANGELOG.md @@ -8,27 +8,19 @@ All notable changes to this project will be documented in this file. - **A meter the panel reports without a breaker space** gets power, energy and current sensors, no switch, and its own place outside the breaker grid. - **Circuits that share a meter or relay name each other**, the panel view draws them as one slot, and current monitoring uses their combined rating. -- **An EV charger lock** where the panel lets the charger be locked, and **busbar current, line frequency and upstream protection rating** sensors where the panel - publishes them. +- **An EV charger lock** where the panel lets the charger be locked, and **busbar current, line frequency and upstream protection rating** sensors where the + panel publishes them. - **A battery the panel declares gets its device before its first reading**, reading unknown until then, and a battery fed by a circuit reports its connection. - **Registration says when to retry** if the panel limits attempts, and setup asks only for the passphrase where the panel does not support proximity. ### Changed - **Circuits with a solar role read and display as generation**, and solar fed through such a circuit gets a Solar device without a separate inverter device. -- **A panel that publishes no solar source no longer gets a Solar device or PV Power sensor**; on an upgraded install those entities stay unavailable until removed. -- **New installs no longer create the Status Postal Code and Status Time Zone sensors**; existing ones stay and keep updating, and diagnostics redact both values. +- **A panel that publishes no solar source no longer gets a Solar device or PV Power sensor**; on an upgraded install those entities stay unavailable until + removed. +- **New installs no longer create the Status Postal Code and Status Time Zone sensors, which say where the panel is installed**; existing ones stay and keep + updating, and diagnostics redact both values. - **The panel view draws only the breaker positions the panel has**, and shows a battery charge the panel has not reported as unknown rather than 0%. - -### Fixed - -- **An energy counter reading beyond what its breaker could ever carry is never used as the dip-compensation baseline**, so it cannot skew energy totals. -- **The current-monitoring summary is hidden while monitoring is off**, instead of reading "0 circuits". - -## [2.1.3] - 10/2026 - -### Changed - - **Setup stops with a repair issue when the panel reports a hardware version this release has not been validated with.** ### Removed @@ -38,6 +30,10 @@ All notable changes to this project will be documented in this file. ### Fixed +- **An energy counter reading beyond what its breaker could ever carry is never used as the dip-compensation baseline**, so it cannot skew energy totals. +- **The current-monitoring summary is hidden while monitoring is off**, instead of reading "0 circuits". +- **DSM State, DSM Grid State and Current Run Config stay on-grid on a panel with no Microgrid Interconnect Device**, instead of dropping to unknown for a + moment whenever Grid Power read near zero. - **Power sensors show unknown while the panel is offline, and Battery, PV, Grid and Site Power show unknown whenever the panel has not published them**, instead of a false 0 W that history and statistics could not tell from a real reading. - **Get monitoring status reports no current or utilization for a circuit or main breaker that has not been measured yet**, instead of 0 A and 0%.